![avago megaraid storage manager incorrect temperature avago megaraid storage manager incorrect temperature](https://i.ytimg.com/vi/ZFJvMiMlP5Q/maxresdefault.jpg)
- Avago megaraid storage manager incorrect temperature how to#
- Avago megaraid storage manager incorrect temperature install#
- Avago megaraid storage manager incorrect temperature full#
- Avago megaraid storage manager incorrect temperature pro#
- Avago megaraid storage manager incorrect temperature software#
I had a 8 drive RAID hooked up directly to the LSI 9260-8i. Looking at what the LSI MegaRAID Storage Manager says about the HPSASEXPcard is that it's Product Revision Level 2.08. But a select few are saying it's an issue with the firmware and should be updated. I googled the messages and most people say that it's just an issue with the RAID card trying to talk to the HDD through the SAS expander card and not an issue.
Avago megaraid storage manager incorrect temperature software#
Anyway, the LSI management software in Windows is initializing, but scrolling tonnes of error messages. I backed up my stuff and trying to create new RAID one RAID with Enterprise class hard drives, and another RAID with just desktop hard drives (yes, I know that can be unreliable - money is tight and slowly migrating to the Enterprise ones). I've had the raid card for a while, but needed to expand larger than the 8 disks. I bought this card on eBay a couple of weeks ago.Īnd I'm hooking it up to an LSI SAS MegaRAID 9260-8i RAID card. This is a really old thread, I'm hoping someone is still checking in. I know this is my first post here, but I hope to be making a home here to discuss my server setup and any future configs. Is this possible with MegaRaid Storage Manger or possibly with MegaCLI or another CLI program? It doesnt break them down by Port or any other organization method. Since I am using the SAS Expander, all of the drives show Slot: 0, SATA, 1.819TB. I tried the Blink Drive option but that doesnt seem to do anything.
Avago megaraid storage manager incorrect temperature how to#
So to go with my question above, I am trying to figure out how to tell what drive is failing if one does. I mainly store Movies and TV Shows on it, so there isnt much of a load most of the time. Over the weekend I tested out a simulated drive failure and it rebuilt the missing drive in about 6hrs with light server load. I am quite happy with these results since the old Adaptec setup was max at about 400MB/s on a good day. HD Tune shows a pretty solid 1.6-1.8GB/s for most of the array. Running Atto, I am consistent at 1.8GB/s Write performance and 2GB/s Read. I ended up with a 23x2TB in Raid6 and a Hot Spare. I proceeded to setup a few arrays to test performance and settings. To my surprise it all booted up and all 24 drives were detected.
![avago megaraid storage manager incorrect temperature avago megaraid storage manager incorrect temperature](https://jakebillo.com/wp-content/uploads/2017/10/esxi-65-enable-ssh.png)
I got all of the data transferred off the old array and was ready to swap for the new parts.
Avago megaraid storage manager incorrect temperature full#
I ended up with a LSI 9270-8i Raid card and I wanted to create a full 24x2TB setup in Raid6 with a single Hot Spare drive. Once the drives started filling up, I decided a month ago to switch things up a bit for a more powerful Raid adapter and I went with one of the HP 6Gb/s SAS Expanders.
![avago megaraid storage manager incorrect temperature avago megaraid storage manager incorrect temperature](http://ottoserver.com/pcserver1/wp/wp-content/uploads/2012/09/92-400x281.jpg)
Avago megaraid storage manager incorrect temperature pro#
I ran it with 16x2TB in Raid6 and a 8x2TB in Raid6 on a Windows 7 Pro OS. I setup, a couple years ago, a Norco 4224 system with 2x cheap 16-port SAS Adaptec Raid Controllers that worked well for me. If I could manualy name them, that would be even better. My question is, is there a way to name the PD ports in MegaRaid Storage Manager for the SAS Expander? I would like to at least be able to name the drive for the SAS Port and the drive off that port at the very least. I have been lurking for years on this thread and reading through things and learning about Expanders. The 2 resources I used to get this working are below, take a look through them you should have no issue getting your MSM up and running.This thread is Massive and I have been trying to go through every page to find the info I am looking for but I haven't found it yet. Add the IP address for both the hostname and the FQDN of your ESXi host. You will need to select “all file types” to be able to see it. Right click on Notepad and select “Run as Administrator.” Open your system hosts file, which can be found at c:\windows\system32\drivers\etc. On your Windows virtual machine, you need to edit the hosts file so it can communicate with the esx host. Lastly there is a tricky step needed on the VM guest so that it can communicate with the host.
Avago megaraid storage manager incorrect temperature install#
Also be sure to install the vib using the the "no-sig-check" parameter. Before installing the VIB make sure to change your host acceptance level to "community supported" and enter maintenance mode. However there are a couple gotchas in those seemingly easy instructions. Peter Zhabin is absolutely correct with his instructions on needing to install the VIB and setting up the CIM service and firewall rules. Having done this exact scenario on 2 different servers I can vouch that installing the MSM on a VM to manage the health of the RAID card on the host is very much doable.